Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arq. bras. oftalmol ; 82(6): 488-494, Nov.-Dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1038692

RESUMO

ABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.


RESUMO Objetivos: Este estudo aborda os resultados refrativos, topográficos, acuidade visual e tomografia de coerência óptica, 12 meses após a inserção do segmento de Anel de Ferrara em túnel corneano a 60% de profundidade com o laser de femtosegundo, em pacientes com ceratocone. Métodos: Série de casos não comparativos, prospectivos e intervencionistas. Realizamos a inserção do Anel de Ferrara através de incisão com o laser de femtosegundo em 15 olhos ceratocônicos. Foram incluídos pacientes com ceratocone documentado que voluntariamente assinaram consentimentos informados que tivessem melhor acuidade visual corrigida ≥0.30 tabela logMAR, espessura corneana ≥400µm. Foram excluídos pacientes com cirurgia ocular prévia ou curvatura corneana > 65 dioptrias (D). As principais variáveis medidas foram acuidade visual corrigida e os parâmetros topográficos da córnea (ceratometria mais plana (K1), mais curva (K2) e ceratometria média (K médio), avaliadas no pré-operatório e com 1, 3, 6 e 12 meses de seguimento. Resultados: A média ± desvio padrão da acuidade visual sem correção e acuidade visual corrigida foi 1.03 ± 0.46 e 0.42 ± 0.13, respectivamente; o desvio padrão médio de 12 meses, a acuidade visual sem correção e acuidade visual corrigida foram de 0.72 ± 0.37 e 0.31 ± 0.16, respectivamente, sem diferenças significativas (p=0,05 para ambos). A melhora da acuidade visual corrigida foi estatisticamente significante após 3 meses (p=0,02), e após 6 meses (p=0,02). Os valores médios da linha de base K1, K2, e média (K médio) foram 48,35 ± 3,65D, 53,67 ± 3,38D, e 50,84 ± 3,36D, respectivamente. A média de 12 meses ± desvio padrão para K1, K2, e K médio foi 46,53 ± 3,70D, 49,83 ± 3,50 D, e 48,12 ± 3,49D respectivamente, com diferença estatisticamente significativas para todos os 3 parâmetros topográficos (p=0,01). Conclusões: A inserção do Anel de Ferrara a uma profundidade de 60% no estroma corneano produz resultados visuais, refracionais e ceratométricos satisfatórios em olhos com ceratocone.


Assuntos
Humanos , Masculino , Feminino , Adulto , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Implantação de Prótese/métodos , Ceratocone/cirurgia , Ceratocone/fisiopatologia , Valores de Referência , Fatores de Tempo , Tonometria Ocular/métodos , Estudos Prospectivos , Resultado do Tratamento , Estatísticas não Paramétricas , Topografia da Córnea/métodos , Tomografia de Coerência Óptica , Cirurgia da Córnea a Laser/métodos , Paquimetria Corneana/métodos
2.
Arq. bras. oftalmol ; 80(2): 88-92, Mar.-Apr. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-838798

RESUMO

ABSTRACT Purpose: To evaluate whether reducing eyelid muscular force through the administration of botulinum toxin type A (BTX-A) to the orbicularis oculi muscles of patients with keratoconus affected corneal parameters indicative of disease progression. Methods: In this prospective parallel randomized clinical trial, 40 eyes of 40 patients with keratoconus were randomized into equally sized control and BTX-A groups. Patients in the BTX-A group received subcutaneous BTX-A injections into the orbicularis muscle. The control group received no intervention. Palpebral fissure height, best spectacle-corrected visual acuity (BSCVA), and corneal topographic parameters were evaluated at baseline and at 3-, 6-, 12-, and 18-month follow-ups. Results: The mean ± standard deviation vertical palpebral fissure heights were 9.74 ± 1.87 mm and 9.45 ± 1.47 mm at baseline in the control and BTX-A groups, respectively, and 10.0 ± 1.49 mm and 9.62 ± 1.73 mm at 18 months, with no significant difference between the groups (p=0.337). BSCVA values were 0.63 ± 0.56 and 0.60 ± 0.27 at baseline in the control and BTX-A groups (p=0.643), and 0.52 ± 0.59 and 0.45 ± 0.26 at 18 months, again with no significant difference between the groups (p=0.452). In addition, there were no statistical differences between the groups at 18 months for the three keratometry topographic parameters: flattest (K1), steepest (K2), and mean (Km) keratometry (p=0.562). Conclusion: BTX-A inhibition of eyelid force generation did not result in detectable changes in corneal parameters in keratoconic patients during 18 months of follow-up.


RESUMO Objetivo: Avaliar se a administração da toxina botulínica tipo A (BTX-A) no músculo orbicular de pacientes com ceratocone a fim de reduzir a força muscular palpebral pode alterar os parâmetros corneanos indicativos de progressão da doença. Métodos: Ensaio clínico randomizado paralelo prospectivo. Quarenta olhos de 40 pacientes, randomizados em grupo controle ou grupo BTX-A na razão de 1:1. Pacientes do grupo BTX-A foram submetidos à injeção subcutânea da toxina botulínica tipo A no músculo orbicular. Os pacientes do grupo controle não sofreram nenhuma intervenção. Foram avaliados a medida da fenda palpebral, melhor acuidade visual corrigida, e topografia corneana nos momentos pré-operatório, e aos 3-,6-,12-, e 18 meses de seguimento. Resultados: Média ± DP (desvio padrão) da fenda palpebral no pré-operatório nos grupos controle e BTX-A foram 9,74 ± 187 e 9,45 ± 1,47 mm, respectivamente; aos 18 meses, a média da altura da fenda palpebral vertical nos grupos controle e BTX-A foram 10,0 ± 1,49 mm e 9,62 ± 1,73 mm, respectivamente, sem diferença significante entre os grupos (p=0,337). A média pré-operatória da melhor acuidade visual corrigida nos grupos controle e BTX-A foram 0,63 ± 0,56 e 0,60 ± 0,27, respectivamente (p=0,643); aos 18 meses, a média nos grupos controle e BTX-A foram 0,52 ± 0,59 e 0,45 ± 0,26, respectivamente, sem diferença significante entre os grupos (p=0,452). Não houve diferença estatística entre os grupos aos 18 meses para todos os parâmetros topográficos ceratométricos avaliados, mais plano-(K1), mais curvo-(K2), e ceratometria média Km (p≥0,562). Conclusão: A inibição da força muscular palpebral pela toxina botulínica tipo A não causou alterações detectáveis nos parâmetros corneanos em pacientes com ceratocone, com 18 meses de seguimento.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Progressão da Doença , Toxinas Botulínicas Tipo A/uso terapêutico , Pálpebras/fisiopatologia , Ceratocone/tratamento farmacológico , Fármacos Neuromusculares/uso terapêutico , Acuidade Visual , Protocolos Clínicos , Estudos Prospectivos , Toxinas Botulínicas Tipo A/administração & dosagem , Topografia da Córnea , Pálpebras/efeitos dos fármacos , Músculos Faciais/efeitos dos fármacos , Paquimetria Corneana , Injeções Subcutâneas , Ceratocone/fisiopatologia , Fármacos Neuromusculares/administração & dosagem
3.
Arq. bras. oftalmol ; 75(2): 101-106, mar.-abr. 2012. graf, tab
Artigo em Inglês | LILACS | ID: lil-640155

RESUMO

PURPOSE: To report the impression cytologic results after corneal cross-linking and insertion of intrastromal corneal ring segments for keratoconus. METHODS: Thirty-nine eyes were distributed into two groups: 1) cross-linking group (patients underwent corneal cross-linking procedure), and 2) riboflavin eyedrops group (patients received 0.1% riboflavin (w/v) eyedrops in 20% dextran solution for 1 month). After 3 months, all patients underwent insertion of intrastromal corneal ring segments. Impression cytologic specimens were obtained from all eyes at baseline, at 1 month and 3 months after cross-linking or riboflavin eyedrops, and again at 6 months, 1 year, and 2 years after intrastromal corneal ring segment insertion. RESULTS: Patients in the cross-linking group demonstrated improvement in the cell-to-cell contact of epithelial cells and the nucleus-to-cytoplasm ratio on the temporal conjunctiva after treatment (P=0.008 and P=0.047), respectively. On the superior conjunctiva, increases in goblet cell density (P=0.037) and level of organization of nuclear chromatin (P=0.010) after treatment were noted. Patients in the riboflavin eyedrops group demonstrated improvement in the cell-to-cell contact of epithelial cells on the superior conjunctiva after treatment (P=0.021). On the temporal conjunctiva, an improvement in the cell-to-cell contact of epithelial cells (P<0.001) and increases in the nucleus-to-cytoplasm ratio (P<0.001), goblet cell density (P=0.001), and less keratinization (P=0.011) were noted. No changes were identified on the cornea for either group. Fisher's exact test comparison of the impression cytologic total scores after treatment revealed no difference between groups. CONCLUSION: Despite changes in some conjunctival parameters (e.g., cell-to-cell contact of epithelial cells, nucleus-to-cytoplasm ratio, level of organization of nuclear chromatin, goblet cell density, and keratinization), comparison of the total impression cytologic scores revealed no difference between groups.


OBJETIVO: Relatar os resultados de citologia de impressão após o "cross-linking" da córnea e inserção dos segmentos de anéis corneanos intraestromais para ceratocone. MÉTODOS: Trinta e nove olhos foram distribuídos em dois grupos: pacientes no grupo cross-linking foram submetidos ao procedimento do "cross-linking" corneano e pacientes no grupo colírio de riboflavina receberam o colírio de riboflavina 0,1% (w/v) -20% dextran para uso tópico por um mês. Após três meses, todos os pacientes foram submetidos à inserção dos segmentos de anéis corneanos intraestromais. Citologia de impressão foi realizada em todos os olhos no pré-operatório, um mês e três meses após o "cross-linking" ou colírio de riboflavina, e novamente com seis meses, um ano e dois anos após a inserção dos segmentos de anéis. RESULTADOS: Pacientes do grupo "cross-linking" apresentaram melhora na adesividade das células epiteliais e proporção núcleo: citoplasma na conjuntiva temporal após o tratamento (P=0,008 e P=0,047), respectivamente. Na conjuntiva superior, houve um aumento na densidade das células caliciformes (P=0,037) e nível de organização da cromatina nuclear (P=0,010) após o tratamento. Pacientes do grupo colírio de riboflavina apresentaram melhora na adesividade das células epiteliais na conjuntiva superior após o tratamento (P=0,021). Na conjuntiva temporal, houve melhora na adesividade das células epiteliais (P<0,001), aumento na proporção núcleo: citoplasma (P<0,001), células caliciformes (P=0,001) e menor queratinização (P=0,011). Ambos os grupos não apresentaram alterações corneanas. O Teste exato de Fisher para comparação de citologia de impressão no escore total após o tratamento não revelou diferença entre os grupos. CONCLUSÃO: Apesar de mudanças em alguns parâmetros conjuntivais (adesividade das células epiteliais, proporção núcleo:citoplasma, nível de organização da cromatina nuclear, células caliciformes e queratinização), a comparação do escore total na citologia de impressão não apresentou diferença entre os grupos.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Implantação de Prótese/métodos , Riboflavina/uso terapêutico , Topografia da Córnea , Terapia Combinada/métodos , Ceratocone/patologia , Ceratocone/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual
4.
Arq. bras. oftalmol ; 74(1): 67-74, Jan.-Feb. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-589945

RESUMO

O cross-linking corneano é um procedimento usado para a estabilização mecânica e aumento da rigidez corneana em pacientes com ceratocone (reduzindo a possibilidade de progressão), e também em processos inflamatórios de afinamento corneano. Os segmentos de anéis corneanos intraestromais têm como princípio o aplanamento central da córnea. Inicialmente utilizados para correção de baixa miopia, a principal indicação atual é em pacientes com ceratocone, para melhorar a acuidade visual não corrigida, a acuidade visual corrigida e permitir uma melhor tolerância ao uso de lentes de contato como também retardar a necessidade de um transplante de córnea. O objetivo deste artigo é revisar algumas publicações relacionadas ao cross-linking corneano e à inserção do segmento de anel intraestromal, apresentando suas indicações, resultados e complicações relatadas até o momento.


Corneal cross-linking is a procedure used for stabilizing the cornea in patients with progressive keratoconus by increasing corneal rigidity, and it is also used in corneal inflammatory melting process. The intrastromal corneal ring segments act by flatting the center of the cornea. Originally designed for the correction of mild myopia, the segments are now being used for reduction of keratoconus in order to improve the uncorrected visual acuity, the best spectacle corrected visual acuity, to allow good tolerance to the use of contact lenses and delay the need for corneal grafting procedures. The present text presents a review of corneal cross-linking and insertion of intrastromal corneal ring segments, emphasizing their indications, results and complications related until now.


Assuntos
Animais , Humanos , Substância Própria/cirurgia , Ceratocone/cirurgia , Implantação de Prótese/métodos , Próteses e Implantes , Fármacos Fotossensibilizantes/uso terapêutico , Implantação de Prótese/efeitos adversos , Riboflavina/uso terapêutico , Raios Ultravioleta , Acuidade Visual
5.
Arq. bras. oftalmol ; 68(1): 93-94, jan.-fev. 2005. tab
Artigo em Português | LILACS | ID: lil-396362

RESUMO

OBJETIVO: Avaliar a adaptação e o uso de lente de contato em pacientes que foram submetidos à cirurgia refrativa. MÉTODOS: Foi realizado estudo retrospectivo de 53 pacientes submetidos à cirurgia refrativa, que posteriormente passaram a usar lente de contato, no período de 1999 a 2003. Foram avaliados a ametropia prévia, tipo de cirurgia realizada, refração pós-cirúrgica, equivalente esférico pós-cirurgia, ceratometria pós-operatória, curva base da lente adaptada, tipo de lente de contato adaptada, acuidade visual com óculos no pós-operatório, acuidade visual final com lente de contato, complicações e motivo da interrupção do uso. O tempo de seguimento variou de 1 mês a 84 meses (média de 42,5 meses). RESULTADOS: Dos 53 pacientes analisados, 19 pacientes foram submetidos a LASIK (Laser Assisted in Situ Keratomileusis), 29 pacientes foram submetidos à RK (ceratotomia radial), 4 pacientes foram submetidos a PRK (ceratectomia fotoablativa) e em um paciente não foi possível obter o tipo de cirurgia realizado. Em 61,29 por cento dos pacientes, (57 olhos de um total de 93), foram adaptadas lentes de contato rígidas gás-permeáveis esféricas. Houve melhora da acuidade visual em 60,21 por cento dos casos (AV>20/40), com poucas complicações. CONCLUSAO: Devido ao número cada vez maior de cirurgias refrativas realizadas, espera-se que aumente o número de pacientes insatisfeitos com o resultado no pós-operatório e para os quais o uso de lentes de contato venha a ser a melhor opção. A adaptação de lentes de contato pós-cirurgia refrativa exige conhecimento e dedicação e em geral tem bons resultados principalmente pela melhora da acuidade visual.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adaptação a Desastres , Lentes de Contato , Erros de Refração/cirurgia , Acuidade Visual , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA